The Cementless Femoral Revision Stem Hip Replacement is a hip replacement implant designed for revision procedures where the original femoral stem requires removal or replacement. The hip replacement implant relies on a cementless, press-fit fixation method and uses a tapered geometry, porous surface, and distal longitudinal slots to enhance mechanical stability.
The Cementless Femoral Revision Stem Hip Replacement works within the hip prosthesis system to restore structural integrity when the proximal femur shows bone defects, compromised fixation, or implant loosening. The Cementless Femoral Revision Stem Hip Replacement functions as part of an orthopedic implant solution that adapts to revision challenges while preserving remaining bone stock. The Cementless Femoral Revision Stem Hip Replacement fulfills revision needs without bone cement and aligns with standard surgical instrument set options for canal preparation, trialing, and final implantation.
Tapered Revision Structure
The tapered geometry of the Cementless Femoral Revision Stem Hip Replacement enhances axial and rotational control inside the femoral canal, supporting stable performance within hip replacement implant procedures.
Porous or Sandblasted Surface
The porous or sandblasted surface of the Cementless Femoral Revision Stem Hip Replacement supports long-term biological engagement and improves overall compatibility with the hip prosthesis system.
Extended and Modular Stem Options
Multiple lengths and diameters allow the Cementless Femoral Revision Stem Hip Replacement to bypass damaged segments and match a wide range of revision needs.
Distal Longitudinal Slots
Distal slot features enhance rotational management during femoral revision, improving handling within orthopedic implant workflows.
Dedicated Reamer Compatibility
The Cementless Femoral Revision Stem Hip Replacement is compatible with a standard surgical instrument set used for canal shaping, controlled reaming, and trial fitting.
High-Strength Titanium Alloy Construction
Medical-grade titanium alloy increases durability and contributes to the long-term reliability of the Cementless Femoral Revision Stem Hip Replacement within the hip replacement implant category.
The Cementless Femoral Revision Stem Hip Replacement is appropriate for revision procedures involving:
Loosening or failure of a primary femoral stem
Periprosthetic fractures requiring femoral shaft stabilization
Proximal or diaphyseal bone defects that require reinforced structural support
Revision of implants with migration, subsidence, or insufficient fixation
Reconstruction of the femoral canal using cementless techniques
The Cementless Femoral Revision Stem Hip Replacement integrates smoothly with a surgical instrument set used for canal preparation, reaming, trial components, and alignment assessment, ensuring workflow compatibility across the hip prosthesis system.
Specification
| Brand | JinMing Medical |
|---|---|
| Material | Medical-grade titanium alloy |
| Structure | Tapered stem, diaphyseal press-fit design, distal longitudinal slots |
| Surface Treatment | Porous or sandblasted surface for biological fixation |
| Sizes | Multiple diameters and lengths for various revision scenarios |
| Compatibility | Works with standard hip replacement implant instruments and modular neck systems |
| Certificate | CE, ISO 13485 |
| OEM / ODM | Fully available for design, labeling, and packing requirements |
JinMing Medical has provided orthopedic implant solutions to global medical professionals for more than 20 years. The Cementless Femoral Revision Stem Hip Replacement benefits from this experience through precision engineering, strict quality control, and consistent manufacturing accuracy.
Advanced 5-axis CNC machining and ZEISS CMM verification enable ±0.01 mm precision across the Cementless Femoral Revision Stem Hip Replacement range. Every unit undergoes full inspection procedures aligned with internationally recognized quality standards. The Cementless Femoral Revision Stem Hip Replacement is supported by complete OEM/ODM options, including adjustments in structure, dimensions, labeling, and packaging to meet regional and clinical requirements.
The Cementless Femoral Revision Stem Hip Replacement is trusted by partners in more than 60 countries who rely on JinMing Medical for dependable orthopedic implant manufacturing and long-term product stability.



The Cementless Femoral Revision Stem Hip Replacement is produced under CE- and ISO 13485-certified systems. Each Cementless Femoral Revision Stem Hip Replacement follows full inspection protocols to verify dimensional accuracy, material consistency, and structural reliability.
OEM/ODM services support customization of stem dimensions, modular options, labeling, and packaging, ensuring the Cementless Femoral Revision Stem Hip Replacement integrates seamlessly into distributor portfolios and hospital workflows within the hip prosthesis system and surgical instrument set categories.